GFS Power

DC Power Systems

Select an item from the list below:

Centurion II DC Power System

  • 19″, 2U rack mount shelf with integrated power distribution
  • 90-250 VAC input, Power Factor Corrected
  • 3 power bays accept 1000 or 2000 watt modular rectifiers
  • 111 amp, 6000 watt total max. output capacity, (74 Amp, 4000 Watt, N+1) @ – 48 VDC, (74 Amp, 2000Watt, N+1) @ 24VDC
  • Output temperature compensated for precise battery charging
  • 16 DC circuit breaker distribution capacity, with tripped breaker alarm
  • Master disconnect breakers for two battery banks, with tripped breaker alarm
  • Controller with digital display of system parameters with TCP/IP interface and SNMP monitoring/logging
  • Alarm contacts monitor major system functions
  • Low voltage disconnect built in
  • Easily configures to meet site power requirements

 

Centurion III Shelf with DC-DC Converter

  • 19″, 2U rack mount shelf with integrated power distribution
  • 90-250 VAC input, Power Factor Corrected
  • 2 power bays accept 1000 or 2000 watt modular rectifiers
    • 74 amp, 4000 watt total max. output capacity, (37 Amp, 2000 Watt, N+1) @ – 48 VDC
  • 2 power bays accept DC-DC modules
    • -48V to 12V and -48V to 24V
  • Output temperature compensated for precise battery charging
  • -48VDC circuit breaker distribution capacity with tripped breaker alarm
  • 10 DC circuit breaker distribution capacity, with tripped breaker alarm
  • 1 each DC-DC converter output circuit breaker distribution with tripped breaker alarm
  • Master disconnect breakers for two 48 volt battery banks, with tripped breaker alarm
  • Controller with digital display of up to three system DC system parameters with TCP/IP interface and SNMP monitoring/logging
  • Alarm contacts monitor major system functions
  • Low voltage disconnect built in
  • Easily configures to meet site power requirements

 

Commander DC Power System

  • 19”, 5U rackmount shelf with integrated power distribution
  • 90-250 VAC input, Power Factor Corrected
  • 7 power bays accept 1000 or 2000 watt modular rectifiers
  • 259 amp, 14,000 watt total max. output capacity, (222 Amp, 2,000 Watt, N+1) @ – 54 VDC
  • Output temperature compensated for precise battery charging
  • 18 DC circuit breaker distribution capacity, with tripped breaker alarm, 63 amp max. circuit breaker rating
  • Master disconnect breakers for four battery banks, with tripped breaker alarm
  • Controller with digital display of system parameters with TCP/IP interface and SNMP monitoring/logging
  • Alarm contacts monitor major system functions
  • Low voltage disconnect built in
  • Easily configures to meet site power requirements

 

HFT 22 DC Power System

  • 1U/19” compact enclosure
  • 2 rectifier slots
  • Rectifier output power from 300W/600W
  • User friendly user (LCD) operation interface
  • Wide input voltage range
  • Module design,simple maintenance
  • Compact design, saves valuable floor space
  • Intelligent remote system monitoring and control

 

HFT 45 DC Power System

  • 3U/19” compact enclosure
  • 4 rectifier slots
  • Rectifier output power from 300W/600W
  • User friendly user (LCD) operation interface
  • Wide input voltage range
  • Module design, simple maintenance
  • Compact design, saves valuable floor space
  • Intelligent remote system monitoring and control

 

Integrated DC Power System

  • Precision regulated power supply simultaneously maintains batteries at peak charge and supplies system load.
  • Built-in batteries instantly power load during AC failure–no switch-over delay. 3-5 year average life. Terminals provided for additional external batteries for increased back-up capacity.
  • Terminals provided for easy addition of parallel rectifier. (48V and 24V models only)
  • Automatic low voltage and manual battery disconnect.
  • Numerous front panel monitors–L.E.D. status indicators and digital ammeter/voltmeter.
  • Form C summary failure alarm contacts; loss of internal rectifier output, loss of external rectifier output, LVBD contactor open. AC input failure alarm contacts optional.
  • Numerous protection features–AC input breaker, internal battery breaker, auto thermal shutdown/recovery,  current-limiting, short-circuit and over-voltage protection.
  • 19″ or 23″, 6” forward rack mount brackets provided

 

Scout DC Power System

  • Redundant hot swap rectifiers provide high system reliability
  • Powers transmitters and maintains back-up batteries
  • 100 amp output per module – 200 amp system capacity
  • Controller module provides Web based remote monitoring and alarms, and digital LCD display of DC volts and amps
  • Compact 1U rackmount shelf
  • Optional LVD and power distribution shelf

 

Sentinel DC Power System

  • 19”, 1U rackmount shelf with integrated power distribution and SNMP digital controller
  • 90-250 VAC input, power factor corrected
  • 3 power bays accept 600 watt modular rectifiers, -48V
  • 33 amp, 1800 watt total max. output capacity
  • Output temperature compensated for precise battery charging
  • 4 DC circuit breaker distribution capacity, with tripped breaker alarm
  • Master disconnect breaker for two battery banks, with tripped breaker alarm
  • Controller with digital display of system parameters with TCP/IP interface and SNMP monitoring/logging
  • Alarm contacts monitor major system functions
  • Low voltage disconnect built-in
  • Easily configures to meet site power requirements

 

Site Power System

  • Well regulated noise free output – no interference with sensitive electronic loads
  • Separate Battery Charger output with remote temperature compensation sensor
  • Automatic Boost voltage output after AC power failure quickly recovers battery
  • Low voltage disconnect protects batteries from over discharge
  • Output current indicator LEDs
  • Wide temperature operating range (-40 to +70° C), convection cooled, meets AREMA standards
  • Alarm contacts interface with remote monitor systems

 

Unity Rectifier System

  • 19″ 1U Rack Mount Rectifier Shelf
  • Choice of -48V or +24V DC rectifier shelf
  • Output power from 150W up to 450Watt
  • Optional five-position GMT fuse distribution panel
  • Scalable/adaptable hot swap configuration: N, N+1, N+2
  • Front panel status indicators, output voltage test points and adjustment potentiometers
  • Individual or summary rectifier alarm contacts; Form C
  • Summary fuse panel alarm contacts; Form C
  • Forced air cooling of rectifiers for extended component life
  • 115/230 VAC shelf/rectifier input—easily adapts to available site power
  • GMT fuse panel: Five positions, easy rear panel wiring to loads, fuse access at front
  • Shelf adapts for 19″ or 23″ rack; center or flush mount (four-point cabinet mount optional)

 

UQA 300 DC Power System

  • 19″ 6U Rack Mount Power Shelf
  • 24V DC Power System
  • Output amperage 75A up to 300Amp
  • Power output 1800W up to 7.2 kW
  • User friendly user (LCD) operation interface
  • Wide input voltage range
  • Module design, front access for simple maintenance
  • Compact design, saves valuable floor space
  • Intelligent remote system monitoring and control

 

© GFS Power. Website by Mick's Design.