DC Power Distribution with GMT Fuses

Fuse distribution panel

DC Power Distribution – models FDP-1010 and FDP-2020 for Telecommunication Applications

  • Low profile 19” or 23” Rack Mount Telecom Fuse Panels
  • Polarity insensitive panels work with positive and negative ground systems -/+ 24 or -/+ 48 VDC
  • GMT fuse holders, 15Amp maximum
  • GMT fuses: available ratings include: 1A, 3A, 5A, 7.5A, 10A and 15Amp
  • Dual input buses, each rated at 100Amp
  • Ideal for DC distribution to low power loads in 24V and 48V DC
  • Provide enhanced system reliability via dual input buses, which allow configuration with redundant power sources
  • Model FDP-1010: each input bus accommodates 10 x GMT output fuses in ratings up to 15 amps. (total number of fuses 20)
  • Model FDP-2020: each input bus accommodates 20 x GMT output fuses in ratings up to 15 amps. (total number of fuses 40)
  • Form C alarm contacts provide remote monitoring of input power and blown fuse conditions
  • Front panel LEDs indicate:
    • Normal operation
    • Fuse failure mode
    • User configured external alarm signal
Model Nominal Input/Output Total Fuse Capacity Amps per Bus (Dual Bus) Total Current Capacity
FDP-1010 +/- 24 or 48 VDC 20 100A 200A
FDP-2020 +/- 24 or 48 VDC 40 100A 200A

Ordering information:

  • FDP-1010          20 fuse panel (10 fuses per bus)
  • FDP-2020          40 fuse panel (20 fuses per bus)
  • GMT-1               1Amp fuse
  • GMT-3               3Amp fuse
  • GMT-5               5Amp fuse
  • GMT-7.5            7.5Amp fuse
  • GMT-10              10Amp fuse
  • GMT-15             15Amp fuse

Features:

  • GMT Fuse
  • Form “C” alarm contacts
  • Polarity insensitive panels work with positive and negative ground systems -/+ 24VDC or -/+ 48VDC
  • 1RU (1.75”) in height will configure to 19” or 23” rack mounting

Operating Temperature

  • -20° to +60°C
  • -5° to + 140°F

Compliances

  • NEBS 3 certified

Mechanical

  • Steel case painted flat black with white graphics
  • Mounting ears provided for 19” and 23” rack mount, flush mount or 6” offset
  • 1 RU (1.75”), can be zero clearance mounted directly adjacent to other equipment

Front Panel Details

  • LED status indicators: Normal Operation Fuse Alarm External alarm
  • Easy accessible fuse blocks
  • Spare fuse holder

Alarms

  • Form C alarm contacts for each bus
  • External ground input alarm (bay or rack alarms)

Specifications:

Nominal Input/Output: +/- 24VDC or +/- 48VDC

Total Fuse Capacity:

  • FDP 1010 – 10 GMT fuses per bus
  • FDP 2020 – 20 GMT fuses per bus

Total Current Capacity:

  • FDP 1010: 200 amps (dual 100 amp bus)
  • FDP 2020: 200 amps (dual 100 amp bus)

Fuse Holder & Fuse Rating:

  • 15Amps maximum

GMT Fuses, standard amperages: 1, 3, 5, 7.5, 10 and 15Amp. Other ratings available upon request

Note: Fuses sold separately

Rear Panel Details

  • Input Terminal Block: Two 1⁄4” studs on 5/8” centers
  • Output and Alarm Terminal Blocks: FDP 1010: Barrier Terminal Block; #22 to #10 AWG wire for fork or ring #6 screw FDP 2020: Elevator clamp style terminal block; #26 to #12 AWG wire.
  • Cable Management Bar
  • Clear Lexan cover protects wiring connections

Case Size

Inches Centimeters
H W D H W D
1.75 17 11.5 4.5 43.2 29.2
Weight: 8 pounds / 3.6kg