Space Critical Power Solutions

  24V 22Amp

 Home
Back
 

 

Integrated Power Systems

The Integrated Power System (IPS) is a unique multifunction power supply which incorporates built-in battery back-up and numerous power accessories within a single 2RU (3.5") chassis, thus eliminating time-consuming system integration, component sourcing and installation, while saving precious rack space--ideal for any low-to-medium power application requiring AC fault tolerant operation.
A precision regulated power supply/charger, back-up battery, low voltage battery disconnect, output metering, LED status and Form C alarm contacts are all pre-wired and calibrated within the unit for plug-and-play operation. Plug-in terminals are provided for easy wiring of an additional parallel rectifier input, or external batteries for increased back-up capacity.
The batteries are always in-line with the load, thus there is no interruption from relays or transfer switches in the event of AC loss. Batteries are recharged when AC is restored. A manual battery disconnect switch allows internal or external battery service or replacement while the system is running. Models available for -48, +24 and +12 volt applications.
 
Features
  • Precision regulated power supply simultaneously maintains batteries at peak charge and supplies system load.
  • Built-in batteries instantly power load during AC failure--no switch-over delay. 3-5 year average life. Terminals provided for additional external batteries for increased back-up capacity.
  • Terminals provided for easy addition of parallel rectifier. (48V and 24V models only)
  • Automatic low voltage and manual battery disconnect.
  • Numerous front panel monitors--L.E.D. status indicators and digital ammeter/voltmeter.
  • Form C summary failure alarm contacts; loss of internal rectifier output, loss of external rectifier output, LVBD contactor open. AC input failure alarm contacts optional.
  • Numerous protection features--AC input breaker, internal battery breaker, auto thermal shutdown/recovery,  current-limiting, short-circuit and over-voltage protection.
  • 19" or 23", 6” forward rack-mount brackets provided
Specifications
 
Model
Input Amps
@ Full Load
115 / 230
Output
 
Internal
Battery
Capacity
 
Ground
Reference
Ground
Reference
VDC
Adjustment
Range
Supplemental
Input Port*
IPS 48-11
11 / 5.5
54.4
40-60 VDC
40 Amps
5 A-H
Positive
Positive
IPS 24-22
11 / 5.5
27.2
20-30 VDC
40 Amps
10 A-H
Negative
Negative
IPS 12-40
11 / 5.5
13.6
10-15 VDC
N/A
20 A-H
Negative
Negative
 
AC Input
 
Input Range (switch selectable):
115V = 92-130 VAC
230V = 184-260 VAC
Frequency: 47-63 Hz
 
DC Output
 
Voltage/Amperage: See Matrix above
Maximum Load with External Rectifier and Battery Inputs: 40 amps
Regulation: Line: ± 1 %, Load: ± 2 %
Ripple: ± 1 %
Power Scaling via Back Panel Quick Connects
External Rectifier Input: 24V, 48V only; 560 or 1,000 watt (see PM Series)
External Battery Bank: 12V/24V/48V
 
Environmental
 
Temperature Rating: -10° to + 60° C; Derate linearly from 100% load @ 50° C to 75% @ 60° C
Mechanical
Chassis: Aluminum
Rack Size: 19" or 23", 2 RU (3.5")
Cooling: Forced Air
Dimensions: 3.5"H x 17"W x 18"D
Weight: 33 Lbs. (with batteries), 17 Lbs. (without batteries)
Protection:
Current Limit, Short Circuit
Over Voltage
Auto Thermal Shutdown/Recovery
Input Fuse and Circuit Breaker
Circuit Breaker For Internal Battery
Low Voltage Battery Disconnect (Adjustable)
 
Internal Batteries
 
Type: 12 Volt, 5 A-H Sealed Lead-Acid, Maintenance-Free
Amp-Hour Capacity: See Matrix below
Weight: 4 Lbs. each; 4 Batteries per Unit
Approvals: UL Recognized, DOT and IATA, approved for shipment by air
 
Internal Battery
Constant Current Performance (Amps) to 1.75 VPC
MODEL
5 MIN.
15 MIN.
30 MIN.
1 HR.
2 HRS.
IPS 48-11
15.0
8.0
5.0
3.0
2.0
IPS 24-22
30.0
16.0
10.0
6.0
4.0
IPS 12-40
40.0
32.0
20.0
12.0
8.0

Indicators and Alarms
 
System "Nominal" indicator lights:
AC OK
External Rectifier ON/OK - Except IPS-12-40
Internal Rectifier On/OK
Battery Contactor Closed
 
System "Warning" indicator lights:
Check System
Battery Disconnected
Form C Alarm Contacts:
Summary Failure
AC Input Failure (Optional)
 
Top View With Cover Removed
Newmar's Integrated Power System Top Cover Removed

 
Options
 
AC Input Fail Contacts - Specify 115 or 230 VAC
Rectifier/Battery Input Cable Assembly (Model CA-24)
Rear Support Bracket for Flush Mounting Models: RSB-19 or RSB-23
DST-10 (UL), DST-20A (UL)
Unit Supplied Without Batteries
 

Download PDF Data Sheet 

Download PDF Installation / Operation Manual 

 

 