Rack Mount Inverter…500VA – 5KVA
The pure sinewave IRM Series inverters are Latronics most versatile and customisable inverter range. The IRM Series is a professional 19″ rack enclosure with a wide range of options to suit individual applications.
A true sinewave output with excellent surge power enables the operation of demanding appliances, such as fridges, microwaves, washing machines and pumps.
Pure Sinewave Waveform
Robust design that protects itself against AC shorts.
Latronics IRM Series Stand-alone inverters are backed by our three year manufacturer’s warranty.
Sophisticated circuitry provides protection against overload, short circuit, over temperature and battery low voltage shutdowns.
Fully selectable between 50/60Hz via a set of internal dip switches for international use
Auto-start circuitry automatically switches the inverter ON and OFF with applied appliances. The Autostart is an important feature as it maximises valuable battery capacity.
Sensitivity of the Autostart can be easily adjusted to either start small appliances or run continuously.
High Efficiency Toroidal Transformer
Toroidal transformers provide outstanding efficiency and durability.
When sized correctly, high surge rating allows easy starting of motors and high inrush current devices.
DC Circuit Breaker/ Battery Isolator Switch
DC Circuit Breaker protects the inverter and cables from becoming a potential fire hazard under fault conditions, as well as providing a point of isolation from your batteries when switched OFF.
The circuit breaker is designed for ease of operation and safety. If the Inverter shuts down due to Overload, Undervolts or Overvolts it can be reset.
Full 3500V AC/DC isolation.
Galvanically isolated.
High quality, high current, heavy duty DC leads for low loss power delivery.
LED Status Indicators
Power indicator (green LED).
This LED flashes when in Standby mode (i.e. no loads connected). When a load is applied the LED will illuminate continuously to indicate that 230V AC is being supplied.
When the Inverter is switched on all 3 LED lights light up for 1 second while the microprocessor performs a start up and system check procedure.
A large range of options from custom voltages and alarm contacts to vibration proofing and conformal coatings are available.
Massive Inrush and Overload Capability.
Rugged Construction.
Inverter Model | IRM512 | IRM624 | IRM648 | IRM696 | IRM6120 | IRM1012 | IRM1224 | IRM1248 | |||||||||||||||||
Nominal DC Voltage | 12V | 24V | 48V | 96V | 120V | 12V | 24V | 48V | |||||||||||||||||
DC Voltage Range | 10-17V | 21-34V | 42-68V | 80-140V | 96-160V | 10-17V | 21-34V | 42-68V | |||||||||||||||||
Continuous Power | 500W | 600W | 600W | 600W | 600W | 1000W | 1200W | 1200W | |||||||||||||||||
30 min Rating | 550W | 750W | 750W | 750W | 750W | 1150W | 1600W | 1600W | |||||||||||||||||
Surge Rate – 5sec | 1500W | 2000W | 2000W | 2000W | 2000W | 3000W | 3600W | 3600W | |||||||||||||||||
Standby Current | 27mA | 22mA | 19mA | 16mA | 15mA | 37mA | 28mA | 22mA | |||||||||||||||||
Inverter ON Idle Current | 0.42A | 0.31A | 0.15A | 0.14A | 0.13A | 0.45A | 0.25A | 0.15A | |||||||||||||||||
Output Waveform | True sinewave <4% THD | ||||||||||||||||||||||||
Output Voltage | 230Vac +/-4%@50Hz+/-0.1% (110Vac 60Hz available as options) | ||||||||||||||||||||||||
Power Factor | All conditions | ||||||||||||||||||||||||
Operating Temp | -10° C to +50° C (can be extended) | ||||||||||||||||||||||||
Load Start Sensitivity | 0-20W | ||||||||||||||||||||||||
DC to AC Isolation | 3500V | ||||||||||||||||||||||||
Peak Efficiency | 90% | 92% | 93% | 93% | 93% | 91% | 92% | 94% | |||||||||||||||||
Dimensions | 3U x 350mm deep (483mm x 134mm x 350mm) | ||||||||||||||||||||||||
Weight | 7kg | 7kg | 7kg | 7kg | 7kg | 12kg | 12kg | 12kg | |||||||||||||||||
DC Circuit Breaker | 2 Pole | 2 Pole | 2 Pole | 2 Pole | 2 Pole | 1 Pole | 1 Pole | 2 Pole | |||||||||||||||||
Output Wiring | Hardwire 3 terminal junction box standard | ||||||||||||||||||||||||
Cooling | Thermostatically controlled fan | ||||||||||||||||||||||||
LED Status Indicators | ON, standby mode, over temperature, over load, Battery under voltage, battery over voltage |
||||||||||||||||||||||||
Protection Circuitry | Full electronic protection against over temperature, overload, short-circuit, battery under voltage and over voltage | ||||||||||||||||||||||||
Standards | AS2279, AS3000, AS3100, EN55014, EN61000-4, CE & C-Tick | ||||||||||||||||||||||||
Warranty | 3 Year | ||||||||||||||||||||||||
Psophonometric Noise (option) | No | No | No | No | No | No | No | Yes | |||||||||||||||||
AC Transfer Switch (option) | Yes | ||||||||||||||||||||||||
Alarm Output (option) | Yes | ||||||||||||||||||||||||
Ratings | Specifications @ 25°C ambient, nominal battery voltage & unity power factor |
Inverter Model | IRM1296 | IRM12120 | IRM1512 | IRM1824 | IRM1848 | IRM1896 | IRM18120 | IRM2012 | |||||||||||||||||
Nominal DC Voltage | 96V | 120V | 12V | 24V | 48V | 96V | 120V | 12V | |||||||||||||||||
DC Voltage Range | 80-140V | 96-160V | 10-17V | 21-34V | 42-68V | 80-140V | 96-160V | 10-17V | |||||||||||||||||
Continuous Power | 1200W | 1200W | 1500W | 1800W | 1800W | 1800W | 1800W | 2000W | |||||||||||||||||
30 min Rating | 1600W | 1600W | 1600W | 2200W | 2200W | 2200W | 2200W | 2200W | |||||||||||||||||
Surge Rate – 5sec | 3600W | 3600W | 4500W | 5400W | 5400W | 5400W | 5400W | 6000W | |||||||||||||||||
Standby Current | 18mA | 17mA | 42mA | 30mA | 24mA | 18mA | 17mA | 75mA | |||||||||||||||||
Inverter ON Idle Current | 0.14A | 0.13A | 0.67A | 0.32A | 0.18A | 0.16A | 0.16A | 1.1A | |||||||||||||||||
Output Waveform | True sinewave <4% THD | ||||||||||||||||||||||||
Output Voltage | 230Vac +/-4%@50Hz+/-0.1% (110Vac 60Hz available as options) | ||||||||||||||||||||||||
Power Factor | All conditions | ||||||||||||||||||||||||
Operating Temp | -10° C to +50° C (can be extended) | ||||||||||||||||||||||||
Load Start Sensitivity | 0-20W | ||||||||||||||||||||||||
DC to AC Isolation | 3500V | ||||||||||||||||||||||||
Peak Efficiency | 94% | 94% | 94% | 91% | 94% | 94% | 94% | 94% | |||||||||||||||||
Dimensions | 3U x 350mm deep (483mm x 134mm x 350mm) | ||||||||||||||||||||||||
Weight | 12kg | 12kg | 12kg | 16kg | 16kg | 16kg | 16kg | 16kg | |||||||||||||||||
DC Circuit Breaker | 2 Pole | 2 Pole | 2 Pole | 1 Pole | 1 Pole | 2 Pole | 2 Pole | 2 Pole | |||||||||||||||||
Output Wiring | Hardwire 3 terminal junction box standard | ||||||||||||||||||||||||
Cooling | Thermostatically controlled fan | ||||||||||||||||||||||||
LED Status Indicators | ON, standby mode, over temperature, over load, battery under voltage, battery over voltage |
||||||||||||||||||||||||
Protection Circuitry | Full electronic protection against over temperature, overload, short-circuit, battery under voltage and over voltage | ||||||||||||||||||||||||
Standards | AS2279, AS3000, AS3100, EN55014, EN61000-4, CE & C-Tick | ||||||||||||||||||||||||
Warranty | 3 year | ||||||||||||||||||||||||
Psophonometric Noise (option) | No | No | No | No | Yes | No | No | No | |||||||||||||||||
AC Transfer Switch (option) | Yes | ||||||||||||||||||||||||
Alarm Output (option) | Yes | ||||||||||||||||||||||||
Ratings | Specifications @ 25°C ambient, nominal battery voltage & unity power factor |
Inverter Model | IRM2324 | IRM2548 | IRM2596 | IRM25120 | IRM3024 | IRM3548 | IRM3596 | IRM35120 | |||||||||||||||||
Nominal DC Voltage | 24V | 48V | 96V | 120V | 24V | 48V | 96V | 120V | |||||||||||||||||
DC Voltage Range | 21-34V | 42-68V | 80-140V | 96-160V | 21-34V | 42-68V | 80-140V | 96-160V | |||||||||||||||||
Continuous Power | 2300W | 2500W | 2500W | 2500W | 3000W | 3500W | 3500W | 3500W | |||||||||||||||||
30 min Rating | 2800W | 3000W | 3000W | 3000W | 3700W | 4100W | 4100W | 4100W | |||||||||||||||||
Surge Rate – 5sec | 7000W | 7500W | 7500W | 7500W | 9000W | 10500W | 10500W | 10500W | |||||||||||||||||
Standby Current | 45mA | 35mA | 24mA | 22mA | 50mA | 40mA | 28mA | 26mA | |||||||||||||||||
Inverter ON Idle Current | 0.51A | 0.3A | 0.22A | 0.21A | 0.6A | 0.33A | 0.24A | 0.23A | |||||||||||||||||
Output Waveform | True sinewave <4% THD | ||||||||||||||||||||||||
Output Voltage | 230Vac +/-4%@50Hz+/-0.1% (110Vac 60Hz available as options) | ||||||||||||||||||||||||
Power Factor | All conditions | ||||||||||||||||||||||||
Operating Temp | -10° C to +50° C (can be extended) | ||||||||||||||||||||||||
Load Start Sensitivity | 0-20W | ||||||||||||||||||||||||
DC to AC Isolation | 3500V | ||||||||||||||||||||||||
Peak Efficiency | 94% | 94% | 94% | 94% | 93% | 94% | 94% | 95% | |||||||||||||||||
Dimensions | 3U x 350mm deep (483mm x 134mm x 350mm) | ||||||||||||||||||||||||
Weight | 22kg | 22kg | 22kg | 22kg | 24kg | 24kg | 24kg | 24kg | |||||||||||||||||
DC Circuit Breaker | 1 Pole | 1 Pole | 2 Pole | 2 Pole | 1 Pole | 1 Pole | 2 Pole | 2 Pole | |||||||||||||||||
Output Wiring | Hardwire 3 terminal junction box standard | ||||||||||||||||||||||||
Cooling | Thermostatically controlled fan | ||||||||||||||||||||||||
LED Status Indicators | ON, standby mode, over temperature, over load, battery under voltage, battery over voltage |
||||||||||||||||||||||||
Protection Circuitry | Full electronic protection against over temperature, overload, short circuit, battery under voltage and over voltage | ||||||||||||||||||||||||
Standards | AS2279, AS3000, AS3100, EN55014, EN61000-4, CE & C-Tick | ||||||||||||||||||||||||
Warranty | 3 year | ||||||||||||||||||||||||
Psophonometric Noise (option) | No | Yes | No | No | No | No | No | No | |||||||||||||||||
AC Transfer Switch (option) | Yes | ||||||||||||||||||||||||
Alarm Output (option) | Yes | ||||||||||||||||||||||||
Ratings | Specifications @ 25°C Ambient, Nominal Battery Voltage & Unity Power Factor |
Inverter Model | IRM5048 | ||||||||||||||||||||||||
Nominal DC Voltage | 48V | ||||||||||||||||||||||||
DC Voltage Range | 42-68V | ||||||||||||||||||||||||
Continuous Power | 5000W | ||||||||||||||||||||||||
30 min Rating | 6000W | ||||||||||||||||||||||||
Surge Rate – 5sec | 15000W | ||||||||||||||||||||||||
Standby Current | 55mA | ||||||||||||||||||||||||
Inverter ON Idle Current | 0.5A | ||||||||||||||||||||||||
Output Waveform | True sinewave <4% THD | ||||||||||||||||||||||||
Output Voltage | 230Vac +/-4%@50Hz+/-0.1% (110Vac 60Hz available as options) | ||||||||||||||||||||||||
Power Factor | All conditions | ||||||||||||||||||||||||
Operating Temp | -10° C to +50° C (can be extended) | ||||||||||||||||||||||||
Load Start Sensitivity | 0-20W | ||||||||||||||||||||||||
DC to AC Isolation | 3500V | ||||||||||||||||||||||||
Peak Efficiency | 95% | ||||||||||||||||||||||||
Dimensions | 3U x 350mm deep (483mm x 134mm x 350mm) | ||||||||||||||||||||||||
Weight | 30kg | ||||||||||||||||||||||||
DC Circuit Breaker | 1 Pole | ||||||||||||||||||||||||
Output Wiring | Hardwire 3 terminal junction box standard | ||||||||||||||||||||||||
Cooling | Thermostatically controlled fan | ||||||||||||||||||||||||
LED Status Indicators | ON, standby mode, over temperature, over load, battery under voltage, battery over voltage |
||||||||||||||||||||||||
Protection Circuitry | Full electronic protection against over temperature, overload, short-circuit, battery under voltage and over voltage | ||||||||||||||||||||||||
Standards | AS2279, AS3000, AS3100, EN55014, EN61000-4, CE & C-Tick | ||||||||||||||||||||||||
Warranty | 3 year | ||||||||||||||||||||||||
Psophonometric Noise (option) | No | ||||||||||||||||||||||||
AC Transfer Switch (option) | Yes | ||||||||||||||||||||||||
Alarm Output (option) | Yes | ||||||||||||||||||||||||
Ratings | Specifications @ 25°C ambient, nominal battery voltage & unity power factor |