Intruder EN50131-6 Series
The GEN Switch Mode range of power supplies has been specifically designed to provide a comprehensive and flexible range for engineers designing Intruder Alarm Systems to grade 2 and 3 under PD6662:2010 / EN50131-6:2008, with built in quality and reliability.
The Range consists of Eight Models:
Grade 2:
- GEN2-08-A
- GEN2-08-B
- GEN2-18-B
- GEN2-18-C
Grade 3:
- GEN3-08-A
- GEN3-08-B
- GEN3-18-B
- GEN3-18-C
GEN Features:
- High Efficiency Switch Mode Operation
- Comprehensive Battery Management
- Deep Discharge Protection
- Battery Fault Detection (Grade 3)
- High Efficiency 3 Stage Charging (18Ah)
- Dedicated Fault Outputs
- EPS Fault (mains fail)
- APS Fault (battery fault) (Grade 3)
- PSU Fault (general fault)
- Internal LED PSU Status
- High Security Front and Rear Tamper (Grade 2 front only)
- Full Rated Current To Load + Battery Charging
- Electronic Overload Protection
- Mains Transient Protection
Output (mains on) | 13.8V dc nominal |
Load Output | 08 Maximum 1.0A - 12 hours @ 580/660mA (7/8Ah) 18 Maximum 1.5A - 12 hours @ 1.4/1.5A (17/18Ah) |
Mains Supply | 90V - 265V a.c @50/60Hz |
Environment | -10C to 40C @ 95%RH |
Enclosure | |
Type A | 200H x 230W x 80D – hinge lid |
Type B | 330H x 355W x 80D – clam lid* |
Type C | 275H x 330W x 80D – hinge lid |
Box Sizes for battery | |
’08′ models | 1 x 7 or 8Ah 1.0A** |
’18′ models | 1 x 17 or 18Ah 1.5A** |
*Communication devices will fit into a ‘B’ size box when used with a 7/8Ah battery. **Full current to load plus additional current to charge standby battery |
GEN range Complies with the following standards::
EN50131-6:2008 GEN2 –Grade 2 GEN3 – Grade 3 All Environmental Class II