GFS Power

Intruder EN50131-6 Series

Intruder series

The GEN Switch Mode range of power supplies has been specifically designed to provide a comprehensive and flexible range for engineers designing Intruder Alarm Systems to grade 2 and 3 under PD6662:2010 / EN50131-6:2008, with built in quality and reliability.

The Range consists of Eight Models:

Grade 2:

  • GEN2-08-A
  • GEN2-08-B
  • GEN2-18-B
  • GEN2-18-C

Grade 3:

  • GEN3-08-A
  • GEN3-08-B
  • GEN3-18-B
  • GEN3-18-C

GEN Features:

  • High Efficiency Switch Mode Operation
  • Comprehensive Battery Management
    • Deep Discharge Protection
    • Battery Fault Detection (Grade 3)
    • High Efficiency 3 Stage Charging (18Ah)
  • Dedicated Fault Outputs
    • EPS Fault (mains fail)
    • APS Fault (battery fault) (Grade 3)
    • PSU Fault (general fault)
  • Internal LED PSU Status
  • High Security Front and Rear Tamper (Grade 2 front only)
  • Full Rated Current To Load + Battery Charging
  • Electronic Overload Protection
  • Mains Transient Protection

Output (mains on) 13.8V dc nominal
Load Output 08 Maximum 1.0A  - 12 hours @ 580/660mA  (7/8Ah)
18 Maximum 1.5A  - 12 hours @ 1.4/1.5A      (17/18Ah)
Mains Supply 90V  - 265V a.c @50/60Hz
Environment -10C to 40C @ 95%RH
Enclosure
Type A 200H x 230W x 80D – hinge lid
Type B 330H x 355W x 80D – clam lid*
Type C 275H x 330W x 80D – hinge lid
Box Sizes for battery
’08′ models 1 x 7 or 8Ah 1.0A**
’18′ models 1 x 17 or 18Ah 1.5A**
*Communication devices will fit into a ‘B’ size box when used with a 7/8Ah battery.
**Full current to load plus additional current to charge standby battery

 

GEN range Complies with the following standards::

EN50131-6:2008      GEN2 –Grade 2        GEN3 – Grade 3           All Environmental Class II

© GFS Power. Website by Mick's Design.