DC Power Supplies – Integrated with Internal Batteries
Integrated Power System (IPS) Series
A unique multi-function power supply which incorporates built-in battery back-up and numerous power accessories within a single 2RU (3.5″) chassis, thus eliminating time – consuming system integration, component sourcing and installation, while saving precious rack space – ideal for any low – to – medium power application requiring AC fault tolerant operation.
A precision regulated power supply / charger, back-up battery, low voltage battery disconnect, output metering, LED status and Form C alarm contacts are all pre – wired and calibrated within the unit for plug – and – play operation. Plug-in terminals are provided for easy wiring of an additional parallel rectifier input, or external batteries for increased back-up capacity.
The batteries are always in-line with the load, thus there is no interruption from relays or transfer switches in the event of AC loss. Batteries are recharged when AC is restored. A manual battery disconnect switch allows internal or external battery service or replacement while the system is running. Models available for -48, +24 and +12 VDC applications.
- Precision regulated power supply simultaneously maintains batteries at peak charge and supplies system load.
- Built-in batteries instantly power load during AC failure – no switch-over delay. 3-5 year average life. Terminals provided for additional external batteries for increased back-up capacity.
- Terminals provided for easy addition of parallel rectifier. (48 V and 24 V models only)
- Automatic low voltage and manual battery disconnect.
- Numerous front panel monitors–L.E.D. status indicators and digital ammeter/voltmeter.
- Form C summary failure alarm contacts; loss of internal rectifier output, loss of external rectifier output, LVBD contactor open. AC input failure alarm contacts optional.
- Numerous protection features–AC input breaker, internal battery breaker, auto thermal shutdown/recovery, current-limiting, short-circuit and over-voltage protection.
- 19″ or 23″, 6” forward rackmount brackets provided
Model | Input Amps @ Full Load 115 / 230 |
Output | Internal Battery Capacity |
Ground Reference |
Ground Reference |
||
VDC | Adjustment Range |
Supplemental Input Port* |
|||||
IPS 48-11 | 11 / 5.5 | 54.4 | 40-60 VDC | 40 Amps | 5 A-H | Positive | Positive |
IPS 24-22 | 11 / 5.5 | 27.2 | 20-30 VDC | 40 Amps | 10 A-H | Negative | Negative |
IPS 12-40 | 11 / 5.5 | 13.6 | 10-15 VDC | N/A | 20 A-H | Negative | Negative |
AC Input
Input Range (switch selectable):
115V = 92-130 VAC
230V = 184-260 VAC
Frequency: 47-63 Hz
DC Output
Voltage / Amperage: See Matrix above
Maximum Load with External Rectifier and Battery Inputs: 40 Amps
Regulation: Line: ± 1 %, Load: ± 2 %
Ripple: ± 1 %
Power Scaling via Back Panel Quick Connects
External Rectifier Input: 24 V, 48 V only; 560 or 1,000 watt (see PM Series)
External Battery Bank: 12V / 24V / 48V
Environmental
Temperature Rating: -10° to + 60° C; Derate linearly from 100% load @ 50° C to 75% @ 60° C
Mechanical
Chassis: Aluminum
Rack Size: 19″ or 23″, 2 RU (3.5″)
Cooling: Forced Air
Dimensions: H 3.5 x W 17 x D 18 inches
Weight: 33 Lbs (15 Kg) with batteries, 17 Lbs (7.7 Kg) without batteries
Protection
- Current Limit, Short Circuit
- Over Voltage
- Auto Thermal Shutdown / Recovery
- Input Fuse and Circuit Breaker
- Circuit Breaker For Internal Battery
- Low Voltage Battery Disconnect (Adjustable)
Internal Batteries
Type: 12 Volt, 5 A-H Sealed Lead – Acid, Maintenance – Free
Amp-Hour Capacity: See Matrix below
Weight: 4 Lbs (1.8 Kg) each; 4 Batteries per Unit
Approvals: UL Recognized, DOT and IATA, approved for shipment by air
Internal Battery Constant Current Performance (Amps) to 1.75 VPC |
|||||
MODEL | 5 MIN. | 15 MIN. | 30 MIN. | 1 HR. | 2 HRS. |
IPS 48-11 | 15.0 | 8.0 | 5.0 | 3.0 | 2.0 |
IPS 24-22 | 30.0 | 16.0 | 10.0 | 6.0 | 4.0 |
IPS 12-40 | 40.0 | 32.0 | 20.0 | 12.0 | 8.0 |
Indicators and Alarms
System “Nominal” indicator lights:
- AC OK
- External Rectifier ON / OK – Except IPS-12-40
- Internal Rectifier ON / OK
- Battery Contactor Closed
System “Warning” indicator lights:
- Check System
- Battery Disconnected
Form C Alarm Contacts:
- Summary Failure
- AC Input Failure (Optional)
Options
- AC Input Fail Contacts – Specify 115 or 230 VAC
- Rectifier / Battery Input Cable Assembly (Model CA-24)
- Rear Support Bracket for Flush Mounting Models: RSB-19 or RSB-23
- DST-10 (UL), DST-20A (UL)
- Unit Supplied Without Batteries
Download Data Sheet and Manuals (PDF)
Integrated_Power_Systems Data Sheet (PDF)
Manual-IPS-48 and 24 (PDF)
Manual-IPS-12-40 (PDF)