48V DC or 24V DC
FUSE DISTRIBUTION PANELS
DUAL
100Amp BUSES
MAX. 20
FUSE PANEL (10 PER BUS)
MAX. 40
FUSE PANEL (20 PER BUS)
CHOICE OF
FUSES: 1A, 3A, 5A, 10A, 15Amp (OTHER RATINGS ON REQUEST)
|

These Fuse Panels are ideal for DC
distribution to low power loads in 24 and 48 volt positive and negative ground
network applications and provide enhanced system reliability via dual input
buses which allow configuration with redundant power sources. Each input bus
accommodates 10 or 20 GMT output fuses (depending on model) in ratings up to 15
amps. Form C alarm contacts provide remote monitoring of input power and blown
fuse conditions. Front panel LEDs indicates normal operation, fuse failure mode,
as well as a user configured external alarm signal. Their low profile 1.75” (1
RU) occupies minimal space and can be configured for 19 or 23 inch rack
mounting.
Model |
Nominal
Input/Output |
Total Fuse
Capacity |
Amps per Bus
(Dual Bus) |
Total Current
Capacity |
FDP-1010 |
+/- 24 or 48VDC |
20 |
100 |
200A |
FDP-2020 |
+/- 24 or 48VDC |
40 |
100 |
200A |
Features
• GMT Fuse
• Form “C” alarm contacts • Polarity insensitive panels work with positive and negative ground systems
-/+ 24 or -/+ 48VDC • 1RU (1.75”) in height will configure to 19” or 23” rack mounting
Operating
Temperature -20° to +60° C -5° to + 140° F
Compliances
NEBS 3 certified
Mechanical
• Steel
case painted flat black with white graphics • Mounting ears provided for 19” and 23” rackmount, flush mount or 6” offset • 1 RU (1.75”), can be zero clearance mounted directly adjacent to other
equipment
Front Panel Details
• LED status
indicators:
Normal Operation
Fuse Alarm
External alarm
•
Easy accessible fuse blocks
•
Spare fuse holder
Alarms
• Form C alarm contacts for each bus
• External ground input alarm (bay or rack alarms)
Specifications
Nominal Input/Output:
+/- 24 or +/- 48VDC
Total Fuse Capacity:
FDP 1010 - 10 GMT fuses per bus
FDP 2020 - 20 GMT fuses per bus
Total Current Capacity:
FDP 1010: 200 amps (dual 100 amp bus)
FDP 2020: 200 amps (dual 100 amp bus)
Fuse Holder & Fuse Rating:
15 amps max.
GMT
Fuses:
Available amperages:
1, 3, 5, 10, 15 Other ratings available upon request
Note: Fuses sold separately
Rear Panel
Details
•
Input Terminal Block:
Two 1⁄4” studs on 5/8” centres
•
Output and Alarm Terminal Blocks:
FDP 1010: Barrier Terminal Block; #22 to #10 AWG
wire for fork or ring #6 screw
FDP 2020: Elevator clamp style terminal block; #26 to #12 AWG wire.
•
Cable Management Bar
•
Clear Lexan cover protects wiring connections
Case Size
Inches |
Centimeters |
(H) 1.75 x (W) 17 x (D) 11.5 |
(H) 4.5 x (W) 43.2 x (D) 29.2 |
Weight: 8 pounds (3.6kg)
Download PDF Data Sheet

Download PDF Installation / Operation Manual: -
Model FDP1010
Download PDF Installation / Operation Manual: -
Model FDP2020
|