LOW VOLTAGE DISCONNECT

NEWMAR -  LVD SERIES (EXTERNAL MOUNTING)

INPUT:  12VDC   12VDC   24VDC   or   48VDC

DISCONNECT:  10.4VDC  10.4VDC  21VDC  42VDC

CONNECT:  12.2VDC  12.2VDC  24.5VDC  49VDC

ADJUSTMENT RANGE:  9-15VDC  9-15VDC  18-30VDC  38-60VDC

Discharging batteries beyond a critical low voltage can damage the batteries and/or load, and require a longer recharge interval. A low voltage disconnect prevents this condition. The LVD contains a sense and control circuit housed in a compact, rugged, vinyl-clad aluminum case. It is installed in-line between the battery and the load. The unit continually monitors battery voltage and if it falls below a preset voltage threshold, the load is automatically disconnected. When batteries are recharged past another pre-set voltage the load is reconnected. Connect and disconnect points are user adjustable.

Download PDF Data Sheet 

 

 

LOW VOLTAGE DISCONNECT & MONITOR

NEWMAR - ULM-100 RACKMOUNT LVD & MONITOR

INPUT:   12VDC   24VDC  or  48VDC

DISCONNECT:  10.4VDC  21VDC  42VDC

CONNECT:  12.2VDC  24.5VDC  49VDC

ADJUSTMENT RANGE:  10-16VDC  20-30VDC  40-60VDC

Digital monitor displays system bus voltage, battery voltage, total rectifier amperage, and connect/disconnect voltage set points,

and system ambient temperature

Download PDF Data Sheet  

 

 

LOW VOLTAGE DISCONNECT, MONITOR & DISTRIBUTION

NEWMAR - PFM-400 RACKMOUNT LOW VOLTAGE DISCONNECT, MONITOR & DISTRIBUTION

INPUT:  12VDC  24VDC  or  48VDC

DISCONNECT:  10.4VDC  20VDC  40VDC

CONNECT:  12.4VDC  24.8VDC  50VDC

ADJUSTMENT RANGE:  +/- 15%  +/-15%  +/-15%

 

Automatic low voltage battery disconnect protects batteries in the event of extended AC power loss

Manual battery disconnect switch allows service/replacement of batteries without system shutdown, 400 amp rating

12, 24 or 48VDC input/output

Use with positive, negative or floating ground

Status lights indicate system and battery connect/disconnect status, assisting technicians in system troubleshooting

Summary alarm contacts (form C) allow remote indication of system status

Separate high amp ground bus provided

Download PDF Data Sheet 

 
 
 
 
 
 